Skip to main content

CDC Debug

❓ Question: CDC step showing Error: Failed to flush Yosys pipe.​

[INFO]: Using inputs/src.f for reading the design
Error: Failed to flush Yosys pipe.
Error in file: scripts/flow_synth.tcl

or The error in the log file could be followings

Executing Verilog-2005 frontend: inputs/fifo.v
inputs/fifo.v:3: ERROR: Re-definition of module `\fifo'!

✅ Answer​

This kind of error occurs when the same design file is compiled more than once, often due to duplication in the source file list.

✔️ Fix:
Review and correct the list of files in src.f or wherever the file list is defined to ensure each file appears only once. Then relaunch Catalyzer.

💡 Tip: Check for both:

  • Manual repetition of the same file path
  • Same file included indirectly via multiple includes